Stb Erom Upgrade Wrong File Software

Posted on by admin
Stb Erom Upgrade Wrong File Software Average ratng: 3,8/5 283 reviews

Public and Factory software images can be updated from Embedded portal (HTTP or USB update methods) to Factory software image only.
To update STB to Public image (provided in Releases at soft.infomir.com) it is necessary to use Bootloader menu Upgrade Tools (USB Bootstrap, MC Upgrade and so on).
Updating STB to custom/other software image (that differs from the factory one) is performed from Embedded portal (HTTP, USB) or MiddleWare. The following instructions should be taken into account:

  • Image making: Image making (PublicImage, CustomImage, OperatorImage)
  • SSH access configuring: SSH

STB software description

Software releases MAG250/254/270

Software versions of STB are released to STB basic models (250, 254, 270). Last releases location:

where:
<model> - mag250, mag254 or mag270
<release> - version of release.

Update from Embedded portal by HTTP

There are two options how to update STB software from manufacrurer's web-server (by HTTP) using the commands of Embedded portal menus:

  • Update from Settings menu;
  • Update from System Settings menu.

When STB runs with standard software image (factory image), software will be updated to the last stable version (factory image) located on manufacturer's server.

Update from Settings menu

  • Open Settings menu of Embedded portal;
  • Choose Software autoupdate;
  • In opened window choose Update manually (F2 on RC).
  • In opened window Software autoupdatechoose list of New versions by pressing OK - The latest available version is on top of the list;
  • Select necessary firmware version;
  • Choose Update (F1);
  • Wait untill STB will be updated. The status of the software update is displayed by progress bar and comments. STB will be rebooted automatically after update.

Update from System Settings menu

  • Go to Settings System settings (or press Setup, Services or Set on the RC - depending on RC type);
  • Open Sofware update.
  • Set Update method = HTTP.
  • Push Verify (ОК). If the test is successful you'll see information about the availability of new versions of software.
  • Push Update (F1) - to begin the update. The status of the software update is displayed by progress bar and comments.
  • At the end of software downloading STB will automatically reboot.
The folowing updating address is set inFactory image (<model> - basic model number: 250, 254, 270):

Note! The string is available for editing via virtual keyboard (brought up by KB key on RC) or USB keyboard.

Update with USB-drive

STB software can be updated using USB-drive. The required software version should be pre-downloaded and written to the USB-drive.

USB-drive requirements

  1. The USB drive must have a FAT32 file system format. If there are more than one partition on the USB drive use the first one.
  2. In case of update from bootloader, if your STB has more than one USB socket, a rear socket is used for upgrade.
  3. Create directorymag<model> (<model> - basic model number: 250, 254 or 270) in a root directory of the USB-drive.

Update from System settings menu

Updating from the System Settings menu of embedded portal allows to update STB software to the factory image.
Note! File bootstrap is not used.

On PC (preparation the USB-drive)

  • Download imageupdate file from manufacture's server: http://update.infomir.com/mag/<model>/imageupdate. For example, for MAG254: http://update.infomir.com/mag/254/imageupdate
  • Put imageupdate file in the USB-drive directory mag<model>. For example, for MAG254:

On STB

  1. Connect prepared USB-drive to STB socket.
  2. Open System settingsSoftware update.
  3. In the window Software update set Update method = USB. You can see two new strings:
    • Disk - name of USB-drive;
    • Path - Path to update file on the USB-drive.
  4. Select Verify (OK) to make sure that the STB detects imageupdate file.
  5. If the file has been detected and can be read you'll see Software Update window.
  6. In Software Update window you can see descriptions of the software versions: the Current version (operating in STB) and New version (available on USB drive).
  7. Determine the need for update comparing Curren and New versions.
  8. To reject update click Cancel in Software Update window.
  9. To begin update click Update (F1) in Software Update window.
  10. Wait until update is complete. Status of software update is displayed by progress bar and comments.
  11. After software loads, STB will automatically reboot.

Update from Bootloader menu

Bootloader menu is launched by user during STB boot. This type of update allows to update STB software to Public image.

Note! File bootstrap should be used. It is located in STB release.

At PC (preparation of USB-drive)

  • If you need to upgrade STB to factory image:
    • Download Bootstrap_<model> file from release of required STB model;
    • Bootstrap_<model> rename to Bootstrap;
    • Download imageupdate file from manufacture's server: http://update.infomir.com/mag/<model>/imageupdate
    • Put imageupdate andBootstrap files in the directory mag<model>
  • If you need to upgrade STB to public image:
    • Download imageupdate and Bootstrap_<model> files from release;
    • Bootstrap_<model> rename to Bootstrap;
    • Put imageupdate andBootstrap files in the directory mag<model>.

    For example, for MAG254:

On STB

  1. Connect prepared USB-drive to STB socket (if there are two USB-sockets - you must use the rear one).
  2. Enter Bootloader menu;
  3. Select Upgrade Tools, open by pressing Right on RC ;
  4. Select USB Bootstrap and confirm with OK;
  5. Wait for updating finish, STB will be rebooted.
Video example of update with USB-drive from Bootloader menu